Let’s start with the main features:
- Compact add-on device
- for 4 to 32 zones in steps of 4
- Additional analogue input 0-10V
- Operation via hot runner control devices
- Flexible visualisation
Let’s start with the main features:
Since 2018 in our assortment the pressure measurement system DMS boasts high filling study precision and enables optimum cycle times during the filling process. The automatic detection of good / bad parts ensures a high degree of automation. The pressure curve indicates whether the temperature for melting the raw material should be increased or reduced in order to achieve an optimised filling of the cavity. The settings for the mould cavity pressure are stored in just one mould data set. The visualisation occurs via the connected temperature controller. DMS can be used irrespective of the sensor brand.
Pressure measurement system
Housing:
Aluminium, colour RAL 5010 gentian blue, special colours available upon request
Dimensions/weight:
See table “equipment designs”
Channels/pressure inputs:
4 to 32 in steps of 4 with 6 pins connection, measuring range 0-2,000 bar, sensitivity 1.5 pC/bar up to 10 pC/bar, 1 analogue pressure input 0-10 V/12-bit
Control inputs:
1 contact input 24VDC for cycle start
1 contact input 24VDC for future extensions
Housing:
Aluminium, colour RAL 5010 gentian blue, special colours available upon request
Dimensions/weight:
See table “equipment designs”
Operation/Visualisation:
via any hot runner control device of the VARIO, fitron TP or JETmaster TP series (software version 3.3 and above, download available under “Good to know”)
Interfaces:
Ethernet to the control device VARIO, fitron TP or JETmaster TP, 1 x Ethernet to the external application
Pressure transducer connection:
See device illustration
Power supply:
110…240 VAC +10…-10 %, 50…60 Hz, 1P / N / PE
Control fuse:
Safety fuse MT 6.3 A, 5 x 20mm
Power supply:
Mains cable with safety plug length 4 m
Ambient temperature:
Operation 0…+55°C, storage -30…+70°C
Climatic application class:
according to DIN 40 040, relative humidity 75% in the annual average, no condensation
Protective system:
IP20
Protection class:
I
Safety:
Manufactured according to IEC 348 (DIN VDE 0411)
CE Marking:
EMC according to 89 / 336 / EEC, EN 50081-2, EN 50082-2
Pressure measurement system
The DMS extends each hot runner controller of the TP and VARIO series by one pressure measurement system – in a handy stack format, easy to transport.
An additional analogue input 0-10V is included as standard, as are 2 Ethernet connections to the TP hot runner controller as well as to the external application.
Customer-specific manufacturing pressure cable for connection the pressure measurement system to the mould
Pressure measurement system
Channel | Type | Item No. | Size (mm) W x H x D | Weight ca. kg |
---|---|---|---|---|
4 | DMS 4 | 1700-0000-04 | 341 x 175 x 250 | 5 |
8 | DMS 8 | 1700-0000-08 | 341 x 175 x 250 | 5 |
12 | DMS 12 | 1700-0000-12 | 341 x 175 x 250 | 5 |
16 | DMS 16 | 1700-0000-16 | 341 x 175 x 250 | 5 |
20 | DMS 20 | 1700-0000-20 | 341 x 175 x 250 | 5 |
24 | DMS 24 | 1700-0000-24 | 341 x 175 x 250 | 5 |
28 | DMS 28 | 1700-0000-28 | 341 x 175 x 250 | 5 |
32 | DMS 32 | 1700-0000-32 | 341 x 175 x 250 | 5 |
Product | |
---|---|
Pressure transducer 2.5 mm | on request |
Pressure transducer 4.0 mm | 910-00-40 |
Pressure transducer 5.0 mm | on request |
Connection cable 1 channel BNC coupling on triax plug 3m | 827-03-14/13 |
Customer-specific connection cable | on request |
Proximity sensor for calculation of the cycle start | 910-00-10 |
Downloads