Needle valve-control – all in one mould data record

Let’s start with the main features:

  • Compact add-on device
  • for 4 to 32 zones in steps of 4
  • 24V DC control mechanism
  • Operation via hot runner control devices
  • Flexible visualisation

Ahead of the competition: Data visualisable via hot runner controller

One of the most recent Fiege electronic top performers is the newly developed needle valve-control of the NVS and NVS plus series. Combined with the temperature controllers of the TP and VARIO series (software version 3 and above), both the needle valve-control and the also newly developed Fiege pressure measurement system can be visualised through an existing hot runner control device. With this development, Fiege yet again sets the standard in terms of ease of operation. NVS is optionally available with end position control and can be used irrespective of the hot runner manufacturer.

Needle valve-control

Technical data

Housing:
Aluminium, colour RAL 5010 gentian blue, special colours available upon request

Dimensions/weight:
See table “equipment designs”

Channels:
4 to 32 in steps of 4

Operation/Visualisation:
via any hot runner control units of the VARIO, fitron TP or JETmaster TP series (software version 3.0 and above, download available under “Good to know”)

Switching outputs:
24V DC/1.25A = 30W per channel

Stroke control:
Up to 1,000 mm, accuracy 0.1 mm

Time control:
Up to 600s, accuracy 0.1s

End position control:
Solenoid valve monitoring with alarm notification

Control inputs:
Contact inputs for: Machine release, injection start and start holding pressure

Alarm notification:
Show on display as well as potential-free alarm contact on the control unit

Interfaces:
Ethernet to the control device VARIO, fitron TP or JETmaster TP, 1 x Ethernet to the external application

Mould connection:
Customised upon request

Power supply:
230 VAC +10…-10%, 50…60Hz, 1P / N / PE, other voltages upon request

Control fuse:
Safety fuse MT 6.3 A, 5 x 20mm

Power supply:
Mains cable with safety plug length 4 m

Ambient temperature:
Operation 0…+55°C, storage -30…+70°C

Climatic application class:
according to DIN 40 040, relative humidity 75% in the annual average, no condensation

Protective system:
IP20

Protection class:
I

Safety:
Manufactured according to IEC 348 (DIN VDE 0411)

CE Marking:
EMC according to 89 / 336 / EEC, EN 50081-2, EN 50082-2

Needle valve-control

The structure

User interface:

Thanks to its practical carry handles, this compact add-on device in a handy stack format can be easily transported.

  1. Hot runner controller
  2. Visualitation
  3. Needle Valve Control System

Device rear view:

Two standard Ethernet connections secure the connection to the hot runner controller as well as to the external application.

  1. Solenoid valve connection
  2. Power supply
  3. Way sensor connection
  4. Controlling signals of the machine
  5. 2 x Ethernet connection

Needle valve-control

Device models:

ChannelsStandardItem No.with end position controlsItem No.Dimensions (mm) W x H x DWeight approx. kg
4NVS 41500-0000-04NVS 4 plus1510-0000-04341 x 260 x 2508
8NVS 81500-0000-08NVS 8 plus1510-0000-08341 x 260 x 2508
12NVS 121500-0000-12NVS 12 plus1510-0000-12341 x 260 x 2508
16NVS 161500-0000-16NVS 16 plus1510-0000-16341 x 260 x 2508
20NVS 201500-0000-20NVS 20 plus1510-0000-20341 x 345 x 25012
24NVS 241500-0000-24NVS 24 plus1510-0000-24341 x 345 x 25012
28NVS 281500-0000-28NVS 28 plus1510-0000-28341 x 345 x 25012
32NVS 321500-0000-32NVS 32 plus1510-0000-32341 x 345 x 25012

Product
Way sensorup to 1000 mm upon request
Connection cable for way sensorupon request
Connection cable for machine signalsupon request
Connection cable for valve actuationupon request
Connection for limit switchesupon request

0000: will be replaced by a custom version number when the order is placed.

Subject to modifications.

Inquire now

Downloads

Find comprehensive product information here:

Contact

Do you have any questions about our products? Our service advisors will be happy to help.

+49 6201 259 58-0 To the form